This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories.
The 2018 IBC contains many important changes such as:
• Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
• New code sections have been introduced addressing medical gas systems and higher education laboratories.
• Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction
based on allowable building area and height.
• Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to
address smoke intrusion into the hoistway.
• The occupant load factor for business uses has been revised to one occupant per 150 square feet.
• Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
• The minimum lateral load that fire walls are required to resist is five pounds per square foot.
• Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again
with ultimate design wind speeds now called basic design wind speeds.
• Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
• Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
Publisher: ICC/2018/3000S18/9781609837358
• New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven
fasteners for the 20-penny nail.
• Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.
Price | $188.95 |
---|---|
Customer Service | Customer ServiceWe're Here To Help Call us anytime during our customer service hours... Monday through Friday - 8:30 am to 4:30 pm (Pacific) Order Questions: TOLL FREE, 800-273-7375 (Outside the U.S. call 818-887-7828). Our Address: 8001 Canoga Avenue Canoga Park, CA 91304 US Phone: 800-275-2665 E-mail: sales@buildersbook.com |
Description | 2018 International Building Code® (IBC®) Soft Cover This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2018 IBC contains many important changes such as: • Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory. • New code sections have been introduced addressing medical gas systems and higher education laboratories. • Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction • Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to • The occupant load factor for business uses has been revised to one occupant per 150 square feet. • Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served. • The minimum lateral load that fire walls are required to resist is five pounds per square foot. • Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again • Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values). • Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
Publisher: ICC/2018/3000S18/9781609837358 • New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven • Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.
|