Residential Duct Systems Manual D. by Hank Rutkowski

Special Price $89.95 Regular Price $99.95
In stock
Product Code
9781892765437
Residential Duct Systems Manual D. by Hank Rutkowski by Air Conditioning Contractors of America.

Design a residential duct system in less time with the streamlined Manual D duct procedure. The newly released Manual D has been significantly revised to include:

  • Updated and expanded VAV guidance, with detailed examples.
  • Impacts of excess length, sag and compression in flexible ducts.
  • New equivalent length values for flex duct junction boxes.

Manual D provides:

  • A single set of ANSI-recognized duct sizing principles and calculations that apply to all duct materials
  • System operating point (supply Cfm and external static pressure), and airway sizing for single-speed and multi-speed (ECM) blowers
  • A method for determining the impact of duct friction and fitting pressure drop on blower performance and air delivery
  • The most comprehensive equivalent length data ever published.

You can apply the Manual D procedure to constant volume systems and zoned variable air volume systems, over a full range of duct construction materials. Manual D includes a number of informative appendices related to air distribution systems (e.g., equipment and air-side components, controlling excess air when VAV dampers close, duct loads, duct leakage and duct system efficiency, air quality issues, noise control, minimum air velocity for ducts; codes, standards and best practice issues; and commissioning issues). 300 pages

Published/Edition: 3rd Edition/2009 ISBN/Book No.: ACCAD/9781892765505/1892765500

More Information
Price$99.95
Customer Service

Customer Service

We're Here To Help

Call us anytime during our customer service hours...


Monday through Friday - 8:30 am to 4:30 pm (Pacific)
Saturday - 10am to 4pm (Pacific)

Order Questions:

TOLL FREE, 800-273-7375 (Outside the U.S. call 818-887-7828).

Our Address:


8001 Canoga Avenue
Canoga Park, CA 91304 US
Phone: 800-275-2665
Fax Your Order
818-887-7990
Print Our Fax Order Form

DescriptionResidential Duct Systems Manual D. by Hank Rutkowski by Air Conditioning Contractors of America.

Design a residential duct system in less time with the streamlined Manual D duct procedure. The newly released Manual D has been significantly revised to include:

  • Updated and expanded VAV guidance, with detailed examples.
  • Impacts of excess length, sag and compression in flexible ducts.
  • New equivalent length values for flex duct junction boxes.

Manual D provides:

  • A single set of ANSI-recognized duct sizing principles and calculations that apply to all duct materials
  • System operating point (supply Cfm and external static pressure), and airway sizing for single-speed and multi-speed (ECM) blowers
  • A method for determining the impact of duct friction and fitting pressure drop on blower performance and air delivery
  • The most comprehensive equivalent length data ever published.

You can apply the Manual D procedure to constant volume systems and zoned variable air volume systems, over a full range of duct construction materials. Manual D includes a number of informative appendices related to air distribution systems (e.g., equipment and air-side components, controlling excess air when VAV dampers close, duct loads, duct leakage and duct system efficiency, air quality issues, noise control, minimum air velocity for ducts; codes, standards and best practice issues; and commissioning issues). 300 pages

Published/Edition: 3rd Edition/2009 ISBN/Book No.: ACCAD/9781892765505/1892765500

Related products

Check items to add to the cart or
Recently Viewed
No recently views items
Clear All